Knowledge

Valve Maintenance

Jun 05, 2025 Leave a message

 External Inspection and Maintenance

  • Valves in long-term storage

1. Regular inspections should be carried out to remove dirt and apply anti-rust oil to the machined surface.
2. Valves should be stored in a dry and ventilated room, and both ends of the passage should be blocked.
3. After installation, regular inspections should be carried out. The main inspection items are: (1) Wear of the trapezoidal threads of the sealing surface, valve stem and valve stem nut. (2) Check whether the packing is outdated and invalid. If damaged, it should be replaced in time. (3) After the valve is repaired and assembled, a sealing performance test is required.

  • Valves in operation

1. Various valve parts should be complete and intact. The bolts on the flange and bracket are indispensable, and the threads should be intact and no looseness is allowed. If the fastening nut on the handwheel is found to be loose, it should be tightened in time to avoid wear of the connection or loss of the handwheel and nameplate. If the handwheel is lost, it is not allowed to be replaced with an adjustable wrench, and it should be replaced in time.
2. The packing gland is not allowed to be skewed or have no pre-tightening clearance. For valves in environments that are easily contaminated by rain, snow, dust, sand and other dirt, the valve stem should be installed with a protective cover.
3. The scale on the valve should be kept intact, accurate and clear. The valve's lead seal, cap, pneumatic accessories, etc. should be complete and intact. The insulation jacket should be free of dents and cracks.
4. It is not allowed to knock, stand or support heavy objects on the running valve; especially non-metallic valves and cast iron valves, it is even more prohibited.

ball valve floating type
 Internal Maintenance

  • Grease injection maintenance

The professional maintenance of valves before welding, before production and after production plays a vital role in the operation of valves during the production process. To ensure the normal operation of the valve and extend the service life of the valve, correct, orderly and effective maintenance must be performed to protect the valve.
These aspects should be paid attention to at work.
First, when greasing the valve, pay attention to the pressure problem. During the greasing operation, the greasing pressure changes regularly in peaks and valleys.
The pressure is too high, the greasing port is blocked, the grease in the seal is hardened, or the sealing ring is locked with the valve ball and valve plate. If the grease injection pressure is too high, on the one hand, check the grease injection nozzle. If the grease hole is blocked, replace it according to the situation; on the other hand, if the grease is hardened, use cleaning fluid to repeatedly soften the failed sealing grease and inject new grease to replace it. If the pressure is too low, the seal leaks or fails. Usually, when the grease injection pressure is too low, the injected grease flows into the bottom of the valve cavity, which usually occurs in small gate valves. In addition, the seal model and seal material will also affect the grease injection pressure. Different seal forms have different grease injection pressures (generally, the grease injection pressure of hard seals is higher than that of soft seals).
Second, when greasing the valve, the problem of grease injection amount is often ignored.
There are two situations: on the one hand, the amount of grease injection is small and insufficient, and the sealing surface accelerates wear due to lack of lubricant. On the other hand, excessive grease injection causes waste. Solution: After the grease gun is refueled, the operator selects the valve and grease injection connection method, and accurately calculates the sealing capacity of different valves according to the valve type category. The sealing capacity can be calculated based on the valve size and category, and then the appropriate amount of grease can be reasonably injected.
Third, when greasing the valve, the grease injection effect should be observed. However, in order to ensure the effect of valve grease injection, it is sometimes necessary to open or close the valve, check the lubrication effect, and confirm that the surface of the valve ball or gate is evenly lubricated. Observe whether the pressure, grease injection amount, and switch position are normal during the grease injection operation.
Fourth, when injecting grease, it is also necessary to observe the flushness of the valve diameter and the sealing ring seat. When adjusting the limit, you cannot only pursue the open or closed position, but consider the overall situation. If the open position is flush and the closing position is not in place, the valve will not be closed tightly. Similarly, when adjusting the closing position, you should also consider the corresponding adjustment of the open position. Ensure the right-angle stroke of the valve. For example, if there is an open position interference with the ball valve, the open position limiter can be adjusted inward, and the diameter can be confirmed to be straight and then locked.

Oil Ball Valve
Fifth, when injecting grease, pay attention to the problem of valve body drainage and screw plug pressure relief. After the valve pressure test, the gas and moisture in the sealing chamber valve cavity are pressurized due to the increase in ambient temperature. When injecting grease, it is necessary to first drain and relieve the pressure to facilitate the smooth progress of the grease injection. After grease injection, the air and moisture in the sealing cavity are fully replaced. The pressure in the valve cavity should be released in time to ensure the safety of the valve. After the grease injection is completed, the sewage and pressure relief screw plugs must be tightened to prevent accidents.
Sixth, when injecting grease, pay attention to the problem of uniform grease output. During normal grease injection, the grease output hole closest to the grease injection port will be greased first, then to the low point, and finally to the high point, and the grease will be output one by one. If it is not regular or does not output grease, it proves that there is a blockage and it should be cleared in time.
Seventh, when injecting grease into the valve, pay attention to the problem of the valve in the switch position. The gate valve must be in the closed state during maintenance to ensure that the grease fills the sealing groove along the sealing ring. If it is open, the sealing grease will fall directly into the flow channel or valve cavity, causing waste. Other valves cannot be generalized. The ball valve is generally in the open state during maintenance, and closed maintenance is selected under special circumstances.
Eighth, when injecting grease, do not ignore the grease injection of the valve stem. If lubrication cannot be ensured, the torque will increase during electric operation and the wear parts will be worn, and the switch will be laborious during manual operation. The sliding sleeve or packing on the valve shaft needs to be lubricated to reduce the friction resistance during operation.
Ninth, when injecting grease, the medium should also be considered during transportation, and specific problems should be treated specifically. For example, the quality of diesel and gasoline is different, and the flushing and decomposition ability of gasoline should be considered. In the future valve operation, when encountering gasoline section operation, add grease in time to prevent wear.
Tenth, some ball valves are marked with arrows on the valve body. If there is no English FIOW handwriting, it is the direction of the sealing seat, not as a reference for the medium flow direction, and the valve self-drain direction is opposite. Under normal circumstances, the double-seat sealed ball valve has a two-way flow direction.
Eleventh, after injecting grease, be sure to seal the grease injection port. Avoid impurities from entering or lipid oxidation at the grease injection port. Apply anti-rust grease to the cover to avoid rust. So that it can be used for the next operation.

  • Precautions

When maintaining the valve, pay attention to the problem of water inflow in the electric head and its transmission mechanism. Especially rainwater that penetrates in the rainy season. One is to rust the transmission mechanism or transmission sleeve, and the other is freezing in winter. The torque is too large when the electric valve is operated, which damages the transmission components and makes the motor unloaded or the over-torque protection tripped, making it impossible to operate the electric valve. If the transmission components are damaged, manual operation is also impossible. After the over-torque protection is activated, manual operation is also impossible. If forced operation is performed, the internal alloy components will be damaged.

Send Inquiry