- Standards and definitions of cryogenic valves
Different standards have different definitions for cryogenic valves.
(1) The British valve standard BS6364 "Valves for Low Temperature" is applicable to medium temperature range of -50℃~-196℃;
(2) The American standard MSSSP-134 "Requirements for Low-temperature Valves and Their Valve Bodies/Bonnet Extensions" explains low temperature as "for standard practice, the low temperature range is between -100℃~ -195℃";
(3) Chinese national standard GB/T 24925 "Technical Conditions for Cryogenic Valve" is applicable to medium temperature range of -29℃~-196℃;
(4) Shell valve standard SHELL MESC SPE 77/200 "Valves for Low Temperature and Ultra-low Temperature" is applicable to the medium temperature range of -30℃~-196℃.
(5) According to the liquefaction temperature of various gases under normal pressure, they are generally divided into six temperature levels.
Level one is 0~ -46℃
Level two is -47~-60℃
Level three is -61~-70℃
Level 4 is -71~-101℃
Level 5 is -102~-196℃
Level 6 is below -253℃
Generally, -46~-150℃ is called low temperature, and below -150℃ is called ultra-low temperature.
The definition of cryogenic valves in the petrochemical industry is based on the design temperature of the conveying medium. Generally, valves used in the medium temperature below -40 ℃ are called cryogenic valves, and valves used in the medium temperature below -101 ℃ are called ultra-low temperature valves.

- Design features of cryogenic valves
1. Material selection for cryogenic valves
The working medium of cryogenic valves is not only low in temperature, but also mostly or, and has strong permeability, which determines many special requirements for valve materials. The mechanical properties of steel at low temperatures are different from those at normal temperature. In addition to strength, the important indicator for low-temperature steel is its low-temperature impact toughness. The low-temperature impact toughness of the material is related to the brittle transition temperature of the material. The lower the brittle transition temperature of the material, the better the low-temperature impact toughness of the material. Metal materials with body-centered cubic lattice, such as carbon steel, suffer from low-temperature cold brittleness, while metal materials with face-centered cubic lattice, such as austenitic stainless steel, have impact toughness that is basically not affected by low temperatures.
The materials for pressure-resistant parts such as cryogenic valve bodies and valve covers are usually made of tough materials with good low-temperature strength. Factors such as weldability, machining performance, stability and economy must also be considered. During design, three low temperature levels are commonly used: -46°C, -101°C and -196°C. Low-temperature carbon steel is generally used for -46℃ low-temperature grades, and 300 series austenitic stainless steel is generally used for -101℃ and -196℃ low-temperature grades. This stainless steel has moderate strength, good toughness and good processing performance.
2. Structural design of petrochemical cryogenic valves
(1) Valve cover structural design
An obvious feature of cryogenic valves is that their valve covers generally have a long-neck structure. In GB/T24925 "Technical Conditions for Cryogenic Valve", it is also clearly stated that "the valve covers of cryogenic gate valves, globe valves, ball valves and butterfly valves should be used according to different uses. The temperature requirement is to design a long-neck valve cover structure that facilitates cold preservation to ensure that the temperature at the bottom of the stuffing box remains above 0°C." The design of the extended valve cover structure is mainly to keep the valve operating handle and stuffing box structure away from low-temperature areas, which can not only avoid frostbite for operators caused by too low temperatures, but also ensure that the stuffing box and pressure sleeve are used at normal temperatures to prevent packing damage. The sealing performance is reduced and the service life of the packing is extended. Because at low temperatures, as the temperature decreases, the elasticity of the packing gradually disappears, and the leak-proof performance decreases. Due to medium leakage, the packing and the valve stem freeze, which affects the normal operation of the valve stem. At the same time, the valve stem moves up and down. And scratch the packing, causing serious leakage. Therefore, cryogenic valves must adopt a long-neck valve cover structure. In addition, the long-neck structure also facilitates wrapping of cold insulation materials to prevent the loss of cold energy. Since low-temperature pipelines generally have a thicker cold insulation layer, the long-neck valve cover facilitates cold insulation construction and keeps the packing gland outside the cold insulation layer, which facilitates tightening the gland bolts or adding filler at any time when necessary without damaging the cold insulation layer.
Bonnet extensions are specified in BS6364, MSS SP-134 and SHELL MESC SPE77/200 standards. Among them, BS6364 stipulates the extended dimensions of 15 to 500 meters with cold boxes, and stipulates that the minimum extended length of non-cold boxes should be 250mm; MSS SP-134 includes the requirements for the extended dimensions of 15 to 300 meters with cold boxes and non-cold boxes. In comparison, the extended dimensions of the non-cold box are longer than those specified in BS6364, and the extended dimensions of the cold box are shorter than those specified in BS6364. SHELL MESC SPE 77/200 does not distinguish between cold boxes and non-cold boxes, and stipulates the length of 15 to 1200 in different temperature ranges.
Comprehensive consideration, SHELL MESC SPE 77/200 has a wide range of extended lengths, making it more convenient and reliable to use. If it is used in critical low-temperature situations, you can refer to the SHELL MESC SPE 77/200 standard for design or design according to the special length requirements of the design unit. In addition, when selecting the length, it is also necessary to consider whether the designed thickness of the cold insulation layer is greater than this length. If so, it should be lengthened to match the thickness of the cold insulation layer.

(2) Structural design of drip board
Since the low-temperature medium is transmitted in the valve, in order to avoid or reduce the transmission of the medium temperature to the valve stem and the filling material at its upper end, and prevent these materials from failing due to freezing, a drip plate structure can be added to the valve. Some research institutions have conducted experimental verification on this kind of valve with a drip plate structure, and proved that the upper end temperature of the valve cover with a drip plate is higher. Since the upper part of the extended valve cover has a lower temperature, the valve is usually exposed to the air. Water vapor in the air will liquefy into water droplets when encountering the low-temperature valve cover. The diameter of the drip plate exceeds the diameter of the middle flange, which can prevent low-temperature liquefaction. Water vapor drips on the middle flange bolts to prevent bolt rust from affecting online maintenance. In addition, the drip plate needs to be set outside the cold insulation layer to prevent condensed water from dripping onto the cold insulation layer and the upper part of the valve body, protecting the cold insulation layer and preventing the loss of cooling capacity.
(3) Structural design of pressure relief components
For cryogenic valves with a closed cavity structure, when used in flammable, explosive and easily vaporized media, there are special requirements for the valve sealing structure. The volume of some low-temperature media will increase after vaporization. For example, the volume of liquefied natural gas after vaporization is more than 600 times that of the liquid state. When the valve is closed and the ambient temperature is relatively high, the low-temperature medium in the valve body absorbs the environment. It gradually vaporizes due to moderate heat, and its volume rises rapidly, causing overpressure inside the valve, and even threatening the safety of the valve, causing medium leakage and even fire accidents. In order to ensure the safety of the valve and the factory, such valves are required to have a middle cavity to self-discharge. The pressure structure enables automatic relief when the pressure in the valve cavity is abnormally overpressured. For example, low-temperature gate valves and ball valves have different sealing principles, so there will be obvious differences in pressure relief design. However, different manufacturers have different characteristics in the design of pressure relief structures.
(4) Anti-static and fire-proof structural design
Since cryogenic valves are generally used in flammable and explosive media, anti-static design and fire-proof design are particularly important. The anti-static design mainly conducts current between the valve stem and the valve body in a way similar to a lightning rod, thereby discharging static electricity to eliminate safety hazards and ensure the supply security of the entire system. For example, GB/T24925 clearly stipulates that "for valves with soft seats or soft closing inserts used for flammable vapors or liquids, the design should ensure that the valve body and valve stem have conductive continuity, and the maximum resistance of the discharge path should not exceed 10Ω." The design of the fire-proof structure is mainly aimed at the problem of medium leakage caused by drastic changes in temperature. The design of the fire-proof structure is similar to the design requirements of ordinary valves.
(5) Valve body
The valve body should be able to fully withstand expansion and contraction caused by temperature changes. Moreover, the structure of the valve seat will not be deformed due to temperature changes.
(6) Valve disc
Gate valves use flexible gates or open gates; stop valves use plug-shaped valve discs for their flat seats and needle valves. These structural forms can maintain reliable sealing regardless of temperature changes.
(7) Valve stem
The valve stem needs to be chromium-plated, nickel-phosphorus-plated or nitrided to improve the surface hardness of the valve stem and prevent the valve stem, packing and packing gland (gland) from seizing each other, damaging the sealing packing and causing stuffing box leakage.
(8) Gasket
When selecting gaskets, the low-temperature properties of the gasket material should be considered, such as compression resilience, pre-tightening force, fastening pressure distribution and stress relaxation characteristics.
(9) Stuffing box and packing
The stuffing box cannot be in direct contact with the low temperature section, but is located at the top of the long-neck valve cover so that the stuffing box is far away from the low temperature and works in a temperature environment above 0°C. In this way, the sealing effect of the stuffing box is improved. In the event of leakage, or when low-temperature fluid directly contacts the packing and the sealing effect is reduced, grease can be added from the middle of the stuffing box to form an oil seal layer to reduce the pressure difference in the stuffing box as an auxiliary sealing measure. The stuffing box mostly adopts a two-stage packing structure with a middle metal isolation ring. However, some use other types such as general valve stuffing box structure and double stuffing box structure with self-tightening valve stem.
(10) Upper seal
Cryogenic valves are all equipped with an upper sealing seat structure. The upper sealing surface must be overlayed with cobalt-chromium-tungsten carbide, and then polished after finishing.
(11) Valve seat, valve disc (gate) sealing surface
The closing parts of the cryogenic valve adopt a cobalt-chromium-tungsten carbide surfacing structure. The soft seal structure is only suitable for cryogenic valves with temperatures higher than -70°C due to the large expansion coefficient of polytetrafluoroethylene and becomes brittle at low temperatures, but polytrifluoroethylene can be used for cryogenic valves with temperatures up to -162°C.
(12) Middle flange bolts
Bolts should have sufficient strength because bolts often break due to fatigue when working under repeated loads. Because bolts can easily cause stress concentration at the thread root, bolts with fully threaded structures are used.