Cryogenic Valve Testing Standard System and Scope of Application

Cryogenic valves (operating temperature ≤ -29°C) must undergo rigorous performance verification. Mainstream international standards include:

1. ISO 28921: Applies to cryogenic testing of industrial valves. It specifies a test temperature gradient from -196°C (liquid nitrogen environment) to -29°C and requires valves to maintain a leak-tight seal (e.g., Class A zero leakage as specified in ISO 5208) at low temperatures.

2. BS 6364: Specifically for LNG valves, it mandates 10,000 opening and closing cycle tests at -196°C, with the torque increase not exceeding 20% of the initial value (referring to Shell SPE 77/200).

3. ASME B16.34: Supplements pressure-temperature ratings. For example, at -101°C, the maximum operating pressure of a Class 150 valve must be reduced to 1.38 MPa (derived from the ASME Section II material low-temperature toughness curve).

The domestic standard GB/T 24925-2019 specifies that the pressure holding time for the -46°C low-temperature test must be ≥ 2 hours, and the leakage rate must be ≤ 0.01 × DN mm³/s (DN is the nominal diameter).

cryogenic swing check valve

Key Test Items and Typical Failure Analysis

1. Sealing Test

- Low-temperature Medium Selection: Liquid nitrogen (-196°C) is used for ultra-low-temperature valves, while a dry ice + alcohol mixture (-78°C) simulates medium- and low-temperature operating conditions.

- Common Failures: Shrinkage of the valve seat material results in insufficient sealing pressure (for example, PTFE shrinks by as much as 1.8% at -100°C), necessitating the use of metal seals or reinforced graphite composite materials.

2. Operating Performance Test

- Torque Test Data: The operating torque of a DN50 ball valve at -196°C typically increases by 40%-60% compared to room temperature (according to API 6D Appendix F).

- Solution: Silver plating of the valve stem (reducing the friction coefficient by 30%) or use of low-temperature grease (such as Krytox GPL-205).