Knowledge

What Is a High Pressure Check Valve? Types, Standards and Selection

May 09, 2025 Leave a message

What a High Pressure Check Valve Is

A high pressure check valve is an automatic valve installed in a high pressure piping system to prevent reverse flow of the medium. It has no external operator: the disc is opened and closed by the medium itself. When flow enters the body in the direction shown by the arrow, the pressure of the medium acts on the disc and produces a thrust; once that thrust exceeds the closing load the valve opens. When forward flow decays, the pressure downstream acting on the disc together with the weight of the disc exceeds the upstream force, and the valve closes before the medium can run back.

Because closure depends on flow behaviour rather than on a mechanism, the choice of check valve type has more effect on system behaviour than the choice of almost any other valve: the wrong type produces chatter, water hammer or a high pressure drop.

Main Structural Types

Type Disc motion Characteristics
Swing check valve Disc rotates about a hinge pin outside the flow path Streamlined passage and low pressure loss; single, double and multi-disc versions; less suitable for pulsating flow and tighter seating needs care
Lift check valve Disc slides along the vertical centreline of the body Body similar to a globe valve, good sealing, higher pressure loss; small bore versions often use a ball disc
Piston check valve Piston guided in a cylinder, spring assisted Fast response, stable under pulsating flow, compact wafer or flanged patterns
Dual plate check valve Two spring loaded plates on a central pin Short face to face length, low weight, fast closing; widely used on large high pressure lines

For very large transmission lines, an axial flow or nozzle type check valve is sometimes selected because the flow passes straight through the body and the pressure loss is the lowest of any check valve design.

Pressure Classes, Materials and Standards

High pressure service generally means Class 900 and above, with Class 1500 and Class 2500 used on transmission and wellhead duties. Pressure temperature ratings are read from ASME B16.34, which derates the working pressure as temperature rises, and flange dimensions follow ASME B16.5 for smaller sizes and ASME B16.47 for large ones. Design and testing of dual plate designs follow API 594, pipeline valves follow API 6D, and shell and seat pressure tests follow API 598.

Body material Typical specification Service
Carbon steel casting A216 WCB General oil, gas and water duty at moderate temperature
Carbon steel forging A105 Small bore and forged valve bodies
Stainless steel A351 CF8M, A182 F316/F316L Corrosive media and low temperature service
Chrome molybdenum steel A217 WC6, WC9 High temperature steam and process lines
Low temperature steel LCB, LC3 Refrigeration and cryogenic duties within the tested range

Performance Characteristics

Compact body. Short face to face length, low weight and easy installation, which reduces the cost of supports and pipework.

Low closing impact. An integral, simple body with a small moving mass closes with limited impact force, which keeps water hammer pressure down and lengthens service life.

Flexible installation. Many designs can be fitted in horizontal or vertical pipe without additional support.

Low flow resistance. An unobstructed passage lets the disc open fully at a small differential pressure.

Reliable sealing. Sealing surfaces are hardfaced or made of tungsten carbide, giving high hardness, erosion resistance and durability on high pressure, high velocity duty.

Applications

Water treatment and pumping. A check valve between the pump discharge and the rising main keeps the column of water from running back when the pump stops, which prevents the pump from reversing and being damaged.

Heating, ventilation and air conditioning. Check valves in chilled and hot water circuits prevent cross flow between supply and return branches and keep the system balanced.

Oil and gas. On gathering and transmission lines, check valves stop reverse flow of liquid or gas, protect compressors and meters, and reduce the risk associated with hydrocarbon migration.

Chemical and process plant. Reverse flow protection between reactors, pumps and storage, where contamination of one stream by another must be prevented.

Boiler feed and steam systems. High pressure check valves protect feedwater pumps and steam headers, with chrome molybdenum bodies and hardfaced trim where temperature is high.

Selection and Installation Guidance

Select the type from the flow conditions first. Steady flow in a large bore can use a swing check valve; pulsating flow from reciprocating pumps is better served by a piston or spring assisted design; tight shutoff in a small bore favours a lift check valve; and space limited, large bore, high pressure lines are usually fitted with dual plate check valves.

Confirm the pressure class and the material from the design pressure, the design temperature and the medium, using ASME B16.34 ratings rather than the nominal class alone. Check that the closing time is compatible with the pump and the pipeline: a check valve that closes faster than the flow can decelerate will produce a pressure surge, while one that closes too slowly allows reverse rotation. Finally, install the valve with the flow arrow aligned to the normal direction of flow, allow the upstream straight length needed for stable flow, and where the line is subject to vibration or thermal movement provide support close to the valve.

FAQ

Q: What pressure class counts as high pressure for a check valve?
In practice, Class 900 and above, with Class 1500 and Class 2500 used on transmission, wellhead and high pressure process duty. The actual allowable pressure must be read from the ASME B16.34 pressure temperature table.

Q: Which check valve has the lowest pressure loss?
A swing check valve or, on very large lines, an axial flow design. A lift check valve has the highest loss of the common types because the flow must change direction around the disc.

Q: Why do high pressure check valves use hardfaced sealing surfaces?
Because at high pressure the velocity across the seat during closing is high, which erodes a soft seating face. Tungsten carbide and hardfacing alloys resist that erosion and keep the seat tight.

Q: Can a check valve prevent water hammer?
It can reduce it. A spring assisted or piston design closes before reverse velocity develops, which limits surge. The valve must still be matched to the pump and pipeline, because a closure that is too fast creates its own pressure wave.

Q: How should a high pressure check valve be installed?
With the body arrow matching the normal flow direction, in an orientation allowed by the design, with adequate upstream straight length and with pipe support close to the valve on lines subject to vibration or thermal movement.

Q: Which tests are carried out before a high pressure check valve is dispatched?
A shell pressure test and a seat tightness test to API 598 at the specified test pressure, together with a material certificate for the body and trim and a dimensional check against the applicable face to face standard.

Send Inquiry