Knowledge

Common causes of failure of pneumatic butterfly valve actuators

May 16, 2025 Leave a message

1. ‌Air source system problems‌
‌Insufficient or unstable air source pressure‌
‌Failure of the air compressor, pipeline leakage or failure of the pressure reducing valve causes the air supply pressure to be lower than the actuator working threshold (0.4-0.7MPa);
In winter, the moisture in the air source freezes and blocks the filter or pressure reducing valve, exacerbating the pressure fluctuation.
‌Air source pollution‌
‌Particulate matter, oil or moisture in the air enters the actuator cylinder, accelerating piston wear and causing seal failure;
Pollutants adhere to the surface of the solenoid valve core, causing the action to be stuck.
2. ‌Abnormal control signal‌
‌Signal loss or distortion‌
‌Signal interruption due to circuit breakage of the solenoid valve circuit, power failure or damage to the control module;
PLC/DCS signal transmission is affected by strong electromagnetic interference or vibration, causing the actuator to malfunction.
‌Electrical component failure‌
‌The solenoid valve coil is burned or the valve core is stuck, and the air path direction cannot be switched;
The positioner bellows leaks or the circuit board is damaged, and the butterfly plate opening cannot be accurately adjusted.

Pneumatic Actuated Butterfly Valves
3. Mechanical failure of actuators

Air leakage and seal failure

Aging and damage of cylinder seal rings lead to internal leakage of pneumatic actuators and decreased output force;
Hardening of valve stem packing (such as graphite asbestos) or damage of "O" rings, leakage at the valve stem.

Mechanical jamming

Movement of piston or gear rack is blocked due to dust accumulation and insufficient lubrication;
Spring of spring return actuator is rusted or broken, and emergency reset cannot be completed.

4. Problems with linkage of valve body

Stuck between butterfly plate and valve seat

Medium particles are embedded in the sealing surface of butterfly plate, or the metal seal ring is stuck due to thermal expansion under high temperature conditions;
Bending and deformation of valve stem lead to increased transmission resistance, and actuator is shut down due to overload.

Insufficient lubrication and wear

The valve stem bearing or gearbox has not been lubricated for a long time, and the increased friction resistance causes slow movement;
Excessive wear of worm gear transmission components and insufficient output torque