API 624 specifies the requirements and acceptance criteria for the low-leakage type testing of rising stem and rising-rotating stem valves equipped with graphite packing. The test determines whether the sealing tightness of such a valve is acceptable, with methane leakage measured against a limit of 100 ppmv based on the principles of EPA Method 21. The graphite packing must be suitable for service from −29 °C to 538 °C (−20 °F to 1000 °F); valves larger than NPS 24 or rated above Class 1500 fall outside the scope. These valves were previously tested under API 622, and no adjustment to the packing area is permitted during the test.
Project Name
Type Testing of Valves with Graphite Packing and Rising Stems

Test Purpose
To determine whether the sealing tightness of valves with graphite packing and rising stems is acceptable.
Test Scope
Valves with graphite packing and rising stems
API 624 Project Overview
The API 624 standard specifies the requirements and acceptance criteria (100 ppmv) for the low-leakage type testing of rising stem and rising-rotating stem valves equipped with graphite packing; such valves were previously tested in accordance with API 622. The packing shall be suitable for service at temperatures from −29 °C to 538 °C (−20 °F to 1000 °F). The requirements included in this type test are based on the principles of EPA Method 21. Valves larger than NPS 24 or with a pressure rating above Class 1500 are outside the scope of this standard.
API 624 Test Result Evaluation
The amount of methane leakage during the test;
No adjustment of any kind to the packing area is permitted during the test.
Test Cycle Diagram

FAQ
Q1. What does API 624 type testing apply to?
A. It applies to rising stem and rising-rotating stem valves equipped with graphite packing. The test determines whether the sealing tightness of such valves is acceptable for process service.
Q2. What is the acceptance criterion in API 624?
A. The limit is 100 ppmv. Methane leakage during the test is measured and judged against this value.
Q3. How does API 624 relate to API 622?
A. Valves with graphite packing and rising stems were previously tested under API 622. API 624 addresses the low-leakage type test at the valve level for this valve configuration.
Q4. What temperature range must the graphite packing suit?
A. The packing must be suitable for service at temperatures from −29 °C to 538 °C (−20 °F to 1000 °F).
Q5. What test principle is the type test based on?
A. The requirements are based on the principles of EPA Method 21, the reference method for measuring fugitive volatile organic compound leakage.
Q6. Which valves are outside the scope of API 624?
A. Valves larger than NPS 24 or with a pressure rating above Class 1500 are outside the scope of the standard.
Q7. Can the packing be adjusted during the test?
A. No. No adjustment of any kind to the packing area is permitted during the test, so the measured leakage reflects the valve as assembled.
Q8. What is actually measured during the API 624 test?
A. The amount of methane leakage during the test. That single measured value, compared with the 100 ppmv criterion, determines whether sealing tightness is acceptable.