Knowledge

What is Diaphragm Type Electrical Remote Control Valve

Dec 29, 2025 Leave a message

The Diaphragm Type Electrical Remote Control Valve controls opening and closing via a solenoid pilot valve, supporting remote operation and allowing for smooth closing by adjusting the closing speed. Depending on its purpose, function, and application, it can be configured as a remote-controlled float valve, pressure reducing valve, slow-closing check valve, flow control valve, pressure relief valve, hydraulic electric control valve, and pump control valve. It is suitable for water supply and drainage systems, high-rise building water supply networks, and urban water supply projects.

 

Core Structure and Working Principle

Drive Mechanism

Comprising a main valve (including valve body, valve stem, and diaphragm) and external control components (solenoid pilot valve, needle valve, and filter), the valve opening and closing is controlled by electrical signals or manual operation.

Hydraulic self-control design utilizes media pressure to drive diaphragm movement, requiring no external lubrication and simplifying maintenance.

Sealing Technology

Diaphragm Seal: Employs an NBR rubber + fabric composite diaphragm to isolate the media from the valve stem components, achieving zero leakage (leakage rate ≤ 0.5% × valve rated capacity).

Multiple Material Compatibility: Valve body options include cast iron (WCB)/stainless steel (CF8M), resistant to corrosive media (pH 0~14).

 

Key Performance Parameters

Parameter Item Technical Specifications Applicable Scenarios
Nominal Pressure 1.0/1.6/2.5/4.0 MPa Select rating based on pipeline working pressure
Medium Temperature 0~80℃ (Conventional) Domestic water supply/fire protection system
Response Speed Solenoid valve control, response time ≤0.05 seconds requiring rapid shut-off in scenarios
Sealing Life Diaphragm fatigue resistance ≥20,000 opening and closing cycles High-frequency operating environment

 

Core Application Scenarios

Fire Protection - Domestic Water Supply Switching

Fire Emergency: Automatically shuts off domestic water supply to ensure fire water pressure; restores domestic water supply after a fire.

Technical Highlights: Three-way solenoid valve control + spring-loaded buffer closure (for water hammer prevention).

Industrial Flow Control

Chemical Industry: Regulates the flow rate of high-viscosity/particulate media; PTFE-lined valve disc is resistant to strong corrosion.

Precision Control: Supports 4-20mA signal input, adjustment accuracy ±3.5%.

 

Diaphragm Type Electrical Remote Control Valve Factory

Diaphragm Type Electrical Remote Control Valve Factory

Contact now

 