The ventilation butterfly valve is a widely used valve in ventilation systems, featuring simple structure, convenient operation, good sealing performance, and a wide flow regulation range. It is typically installed on ventilation ducts to control the direction and flow of air to meet the needs of various applications.
GNEE Group has been manufacturing valves for 18 years, providing valve solutions to the global industrial sector. Industry-Leading Valves – Get a Demo Today!
Ventilation Butterfly Valve Technical parameters
Size Range: DN50-DN4000
Material: WCB, Stainless Steel
Connection Options: Flanged End
Pressure: 0.05Mpa ~ 0.6Mpa
Working Temperature: -29°C to 425°C
Sealing Options: SS304 + Graphite
Applicable Medium: Gas, dust gases, flue gas
Ventilation Butterfly Valve Features
1. Simple Structure: The ventilation butterfly valve adopts a rotary valve disc structure, which is simple in structure and easy to manufacture and maintain.
2. Convenient Operation: The ventilation butterfly valve is easy to operate; simply rotating the valve disc is sufficient to open and close it.
3. Good Sealing Performance: The ventilation butterfly valve uses rubber or metal sealing rings for sealing, providing excellent sealing performance.
4. Wide Flow Adjustment Range: The ventilation butterfly valve has a wide flow adjustment range, which can be adjusted according to actual needs.
5. Strong Corrosion Resistance: The ventilation butterfly valve is usually made of stainless steel or carbon steel, exhibiting good corrosion resistance.
Ventilation Butterfly Valve Specification Parameters
| Item | Specification | ||||
|---|---|---|---|---|---|
| Nominal Diameter | DN (mm) | 50 ~ 4000 | |||
| Nominal Pressure | PN (MPa) | 0.05 | 0.10 | 0.25 | 0.6 |
| Test Pressure | Strength Test (MPa) | 0.075 | 0.15 | 0.375 | 0.9 |
| Seal Test – Sealed (MPa) | 0.055 | 0.11 | 0.275 | 0.66 | |
| Seal Test – Non-Sealed | ≤ 1.5% leakage | ||||
| Applicable Medium | Gas, dust gases, flue gas, etc. | ||||
| Drive Type | Manual, worm gear, pneumatic, electric transmission | ||||
Ventilation Butterfly Valve Main Components Material:
| Part Name | Material |
|---|---|
| Body | Q235A, 16Mn steel, stainless steel |
| Disc | Q235A, 16Mn steel, stainless steel |
| Ring | Q235A, 16Mn steel, stainless steel |
| Stem | 2Cr13, stainless steel |
| Packing | Flexible Graphite |
Ventilation Butterfly Valve drawning

Ventilation Butterfly Valve Main Connection Dimensions:
| DN (mm) | L | H | H0 | 0.05–0.1 MPa | 0.25 MPa | 0.6 MPa | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D | D1 | D2 | n–d | D | D1 | D2 | n–d | D | D1 | D2 | n–d | ||||
| 100 | 127 | 105 | 486 | 210 | 190 | 144 | 4–18 | 210 | 190 | 144 | 4–18 | 210 | 170 | 144 | 4–19 |
| 125 | 140 | 120 | 516 | 240 | 200 | 174 | 8–18 | 240 | 200 | 174 | 8–18 | 240 | 200 | 174 | 8–19 |
| 150 | 140 | 132 | 541 | 265 | 225 | 199 | 8–18 | 265 | 225 | 199 | 8–18 | 265 | 225 | 199 | 8–19 |
| 200 | 152 | 160 | 779 | 320 | 280 | 254 | 8–18 | 320 | 280 | 254 | 8–18 | 320 | 280 | 254 | 8–19 |
| 250 | 165 | 187 | 836 | 375 | 335 | 309 | 12–18 | 375 | 335 | 309 | 12–18 | 375 | 335 | 309 | 12–19 |
| 300 | 180 | 220 | 901 | 440 | 395 | 363 | 12–22 | 440 | 395 | 363 | 12–22 | 440 | 395 | 363 | 12–23 |
| 350 | 180 | 245 | 954 | 490 | 445 | 413 | 12–22 | 490 | 445 | 413 | 12–22 | 490 | 445 | 413 | 12–23 |
| 400 | 200 | 270 | 1003 | 540 | 495 | 463 | 16–22 | 540 | 495 | 463 | 16–22 | 540 | 495 | 463 | 16–23 |
| 450 | 200 | 297 | 1058 | 595 | 550 | 518 | 16–22 | 595 | 550 | 518 | 16–22 | 595 | 550 | 518 | 16–23 |
| 500 | 220 | 322 | 1111 | 645 | 600 | 568 | 20–22 | 645 | 600 | 568 | 20–22 | 645 | 600 | 568 | 20–23 |
| 600 | 220 | 377 | 1233 | 755 | 705 | 667 | 20–26 | 755 | 705 | 667 | 20–26 | 755 | 705 | 667 | 20–26 |
| 700 | 240 | 430 | 1338 | 860 | 810 | 772 | 24–26 | 860 | 810 | 772 | 24–26 | 860 | 810 | 772 | 24–26 |
| 800 | 240 | 487 | 1452 | 975 | 920 | 878 | 24–30 | 975 | 920 | 878 | 24–30 | 975 | 920 | 878 | 24–31 |
| 900 | 260 | 537 | 1588 | 1075 | 1020 | 978 | 24–30 | 1075 | 1020 | 978 | 24–30 | 1075 | 1020 | 978 | 24–31 |
| 1000 | 260 | 587 | 1689 | 1175 | 1120 | 1078 | 28–30 | 1175 | 1120 | 1078 | 28–30 | 1175 | 1120 | 1078 | 28–31 |
| 1200 | 280 | 702 | 1938 | 1375 | 1320 | 1280 | 32–30 | 1375 | 1320 | 1280 | 32–30 | 1405 | 1340 | 1295 | 32–34 |
| 1400 | 300 | 782 | 2670 | 1575 | 1520 | 1480 | 36–30 | 1575 | 1520 | 1480 | 36–30 | 1630 | 1560 | 1510 | 36–37 |
| 1600 | 320 | 895 | 2810 | 1790 | 1730 | 1690 | 40–30 | 1790 | 1730 | 1690 | 40–30 | 1830 | 1760 | 1710 | 40–37 |
| 1800 | 340 | 995 | 3020 | 1990 | 1930 | 1890 | 44–30 | 1990 | 1930 | 1890 | 44–30 | 2045 | 1970 | 1918 | 44–40 |
| 2000 | 360 | 1095 | 3220 | 2190 | 2130 | 2090 | 48–30 | 2190 | 2130 | 2090 | 48–30 | 2265 | 2180 | 2125 | 48–43 |
| 2200 | 380 | 1200 | 3430 | 2405 | 2340 | 2295 | 52–33 | 2405 | 2340 | 2295 | 52–33 | 2475 | 2390 | 2335 | 52–43 |
| 2400 | 400 | 1310 | 3650 | 2605 | 2540 | 2495 | 56–33 | 2605 | 2540 | 2495 | 56–33 | 2685 | 2600 | 2545 | 56–43 |
| 2600 | 420 | 1420 | 3920 | 2805 | 2740 | 2695 | 60–33 | 2805 | 2740 | 2695 | 60–33 | 2905 | 2810 | 2750 | 60–49 |
| 2800 | 440 | 1530 | 4140 | 3030 | 2960 | 2910 | 64–36 | 3030 | 2960 | 2910 | 64–36 | 3115 | 3020 | 2960 | 64–49 |
| 3000 | 460 | 1640 | 4360 | 3230 | 3160 | 3110 | 68–36 | 3230 | 3160 | 3110 | 68–36 | 3315 | 3220 | 3160 | 68–49 |
| 3200 | 480 | 1760 | 4620 | 3430 | 3360 | 3310 | 72–36 | 3430 | 3360 | 3310 | 72–36 | 3525 | 3430 | 3360 | 72–49 |
| 3400 | 500 | 1870 | 4840 | 3630 | 3560 | 3510 | 76–36 | 3630 | 3560 | 3510 | 76–36 | 3735 | 3640 | 3560 | 76–49 |
| 3600 | 520 | 1980 | 5060 | 3840 | 3770 | 3720 | 80–36 | 3840 | 3770 | 3720 | 80–36 | 3970 | 3860 | 3720 | 80–56 |
| 3800 | 540 | 2120 | 5400 | 4045 | 3970 | 3920 | 80–39 | 4045 | 3970 | 3920 | 80–39 | 4180 | 4070 | 3970 | 80–62 |
| 4000 | 560 | 2230 | 5620 | 4245 | 4170 | 4120 | 84–39 | 4245 | 4170 | 4120 | 84–39 | 4380 | 4270 | 4170 | 84–62 |
Ventilation Butterfly Valve Working Principle
By rotating the valve plate (typically within the range of 0° to 90°), the flow area between the valve plate and the valve body is changed:
- Fully Open: The valve plate is parallel to the airflow direction, resulting in minimal flow resistance and maximum flow rate.
- Closed: The valve plate is perpendicular to the airflow direction, completely cutting off the flow.
- Regulated: The valve plate is at the intermediate angle; flow rate is adjusted by changing the opening degree.
Ventilation Butterfly Valve Applications
- Ventilation Systems: Such as factory ventilation, underground parking garage exhaust, tunnel ventilation, etc.
- Air Conditioning Systems: Regulate fresh or return air flow to control indoor temperature and air quality.
- Environmental Engineering: Gas flow regulation in flue gas desulfurization, denitrification, dust removal, and other systems.
- Industrial Pipelines: Gas transmission pipelines in chemical, power, and metallurgical industries.
- Fire Protection Systems: Used in conjunction with smoke exhaust valves or fire dampers for rapid closure in emergencies.