Products
Quiet Check Valves
video
Quiet Check Valves

Quiet Check Valves

A quiet check valve — also called a silent, non-slam or spring-loaded check valve — closes the disc before reverse flow develops, so the water hammer that makes a swing check bang is avoided rather than absorbed. Units run DN50–DN600 (NPS 2–24), Class 150–2500, and reseat in under 0.3 s with head loss near 0.2 bar at 2 m/s.

A quiet check valve is a non-return valve engineered around closure behaviour rather than tightness. Instead of a hinged clapper that waits for gravity or reverse flow, the disc is centre-guided and held closed by a spring, so it travels a short stroke and seats while forward velocity is still decaying. The same geometry that suppresses the slam fixes the valve's limits: a permanent cracking pressure the pump must overcome, a head loss that rises with spring rate, and a seat the standards grade to a looser leakage class than a shut-off valve. This page covers where quiet check valves are used, what the constructions deliver, and the numbers that decide selection, with the API and ASTM references needed to specify them.

 

Technical Specifications

The quiet check valve size range runs from DN50 to DN600 (NPS 2–24), with larger axial-flow sizes to DN1200 on request. Confirm face-to-face against ASME B16.10 and the flange drilling against ASME B16.5 or EN 1092-2 before ordering.

Table 1 - Quiet check valve supply range
Size range DN50–DN600 (NPS 2–24); axial-flow sizes to DN1200 on request
Pressure class Class 150–2500 (ASME B16.34); PN10, PN16, PN25, PN40
Design standard API 594 check valve (Type A wafer / lug / dual-plate; Type B long-pattern swing), API 6D check valve for pipeline service, ASME B16.34 for ratings
End connections Wafer, lug, double-flanged RF/RTJ, butt-weld (ASME B16.25)
Face-to-face ASME B16.10 / API 594 short pattern
Test standard API 598 (shell and seat), ISO 5208 leakage rates, EN 12266-1
Temperature range −46 °C to +425 °C, depending on body and seat material
Cracking pressure 0.07–0.7 bar (1–10 psi) typical for spring designs
Certification MTC to EN 10204 3.1 as standard, 3.2 on request; NACE MR0175 / ISO 15156 option
Commercial MOQ 1 pc; lead time 4–8 weeks; warranty 18 months

 

Body and trim materials

Table 2 - Common body materials (minimum values at room temperature)
Material Form Temp. range Tensile, MPa Yield, MPa
ASTM A216 WCB Cast carbon steel −29 to +425 °C ≥485 ≥250
ASTM A105 Forged carbon steel −29 to +425 °C ≥485 ≥250
ASTM A352 LCB Cast low-temp carbon −46 to +345 °C ≥485 ≥250
ASTM A351 CF8 Cast 304 SS −196 to +425 °C ≥485 ≥205
ASTM A351 CF8M Cast 316 SS −196 to +425 °C ≥485 ≥205
Ductile iron GJS-400-18 (GGG-40) Cast iron −10 to +120 °C ≥400 ≥250

Trim options include 13Cr (Trim 1), Stellite-faced (Trim 5) and 316 SS seats. Springs are usually 304 or 316 SS, with Inconel X-750 for high-cycle or high-temperature service. Resilient seats (EPDM, NBR, PTFE) are chosen for the medium and its temperature, not for the body alloy.

 

Seat leakage: what the standards actually allow

A check valve is not a shut-off valve, and the standards say so by grading check valves to a looser leakage class than other valve types. This is the single most misrepresented point in supplier literature.

Table 3 - Closure-test leakage limits by valve type
Standard Shut-off / other valve types Check valves
ISO 5208 Rate A / AA / CC depending on seat and test fluid Rate G (liquid) and Rate EE (gas) - the two loosest rates
API 6D Rate D (liquid and gas) Rate G (liquid) and Rate EE (gas)
API 598 Metal-seated table in drops/min and bubbles/min Separate check-valve table in cm³/min and m³/min
MSS SP-61 Base table per NPS/DN May take up to four times the base-table rate
ANSI/FCI 70-2 Class II–VI (control valves) Not applicable - the standard is not intended for check valves

Note: Because a check valve's task is to limit backflow rather than to seal tight, "zero leakage" or "Class VI per API 598" has no basis for this valve type. Specify the leakage class the product standard assigns, and state the standard and edition on the order.

 

Structure selection within the quiet family

Table 4 - Choosing between quiet check valve constructions
Construction Typical size Head loss Best for
Spring-loaded single-disc check valve DN15–DN200 Moderate Pump discharge, inline spools, tight spaces
Dual-plate wafer check valve (API 594 Type A) DN50–DN600 Moderate Large-diameter mains, HVAC, retrofit where face-to-face is short
Axial-flow check valve (nozzle type) DN80–DN1200 Lowest Compressor and large pump mains, high-cycle service
Tilting disc check valve DN200–DN1200 Low–moderate High-velocity gas and steam where a swing pattern would slam
Lift check valve DN15–DN100 Highest Small-bore vertical lines with upward flow

 

Port Size Connection H A Kg
2" Flange 183 122 9
21/2" Flange 200 132 12
3" Flange 210 147 14
4" Flange 220 160 16
5" Flange 260 180 27
6" Flange 280 200 32
8" Flange 370 Upon Request 61
10" Flange 450 Upon Request 117
12" Flange 520 Upon Request 138

 

Silent Check Valve in stock

Silent Check Valvessilent check valves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve workshop

valve workshop

Send the following and we will return a technical submittal and itemised price within one working day.

Size and pressure class (DN / NPS and Class or PN)

End connection and face-to-face requirement

Medium, operating temperature and design flow rate

Body and seat material, spring material if specified

Cracking pressure or minimum differential available

Applicable standard and edition, plus leakage class

Quantity, destination port and required documents

Request a Quote

 

Why Source Quiet Check Valves From Us

Spring and seat control: Spring rate is set to the closing behaviour your line needs, and seat material is matched to the medium and temperature, so the valve shuts before reverse flow rather than after it.

Standard discipline: Every offer names the design standard, the test standard and the leakage class that applies to a check valve, so the acceptance criteria on the certificate can be checked against the specification.

Testing on every unit: Shell and seat tests to API 598 are run on each valve with the report supplied; PMI and NACE options are available for sour and critical service.

Manufacturer and supplier: As a China quiet check valve supplier and a quiet check valve manufacturer, we serve EPC contractors, pump packagers and distributors, and act as your single source for project and OEM programs.

 

FAQ

What is a quiet check valve and how does it differ from a silent check valve?

They are the same product. Quiet, silent, non-slam and spring-loaded check valve are interchangeable names for a non-return valve whose disc is spring-assisted and centre-guided so it closes before reverse flow develops. Nozzle or axial-flow check valve describes one construction within that family, not a separate product.

 

How does a quiet check valve stop water hammer?

Water hammer follows the Joukowsky relation ΔP = ρ·a·ΔV, so the surge scales with the reverse velocity at closure. A spring-loaded disc seats while forward flow is still decaying, so ΔV stays near zero and the surge is not generated. A swing check, by contrast, closes after the column has already reversed, which is when the pressure spike occurs.

 

What seat leakage class applies to a check valve?

Check valves are graded to the loosest classes in the standards: ISO 5208 Rate G for liquid and Rate EE for gas, which API 6D also adopts, and MSS SP-61 permits up to four times its base rate. ANSI/FCI 70-2 Class II–VI does not apply to check valves. A quiet check valve limits backflow; it is not a bubble-tight isolation valve.

 

Can a quiet check valve be installed vertically?

Yes. Because the spring rather than gravity drives the disc closed, spring-loaded, dual-plate and axial-flow designs can be installed horizontally or vertically, with either upward or downward flow. A swing check cannot: in a vertical line it needs upward flow, and in horizontal pipe it will not seal against down-flow.

 

What size, pressure class and materials do you supply?

DN50–DN600 (NPS 2–24) as standard, with axial-flow sizes to DN1200 on request, in Class 150–2500 and PN10–PN40. Body materials include ASTM A216 WCB, A105, A352 LCB, A351 CF8 and CF8M, and ductile iron GJS-400-18 for water service, with metal or resilient seats and 304 / 316 / Inconel X-750 springs.

 

What is the minimum order quantity and lead time?

The minimum order quantity is one piece, and a sample valve can be supplied for evaluation. Standard lead time is four to eight weeks depending on size, class and material; stock items ship sooner. Payment terms are flexible and confirmed with the quotation, and every unit is pressure-tested to API 598 before dispatch.

 

What certificates and test reports are supplied?

Each order ships with a material test certificate to EN 10204 3.1 as standard, upgradeable to 3.2, plus the hydrostatic shell and seat test report to API 598. NACE MR0175 / ISO 15156 and ISO 15848-1 documentation, positive material identification and third-party inspection are available on request.

 

Can you supply OEM or ODM production?

Yes. We produce to customer drawings and nameplates, including special face-to-face dimensions, non-standard flange drilling and specific trim combinations. Send the datasheet or drawing with size, class, medium, temperature and leakage class and we will confirm a buildable specification and price.

Hot Tags: quiet check valves, China quiet check valves manufacturers, suppliers, factory, check valve for pipeline, cast iron non return valve, check valve flow control, Iron Valves, check valve customization, Piston Check Valve

Send Inquiry