Products
Electric Ball Valve
video
Electric Ball Valve

Electric Ball Valve

Size: 2″-32″
Pressure: Class 150LB-1500LB
Material: Carbon Steel/Stainless Steel

motorized ball valve Description

Electric ball valve is an important actuator in industrial automation control systems. It operates by rotating the valve disc around the axis of the stem. The change in the valve seat opening is directly proportional to the movement of the valve disc. Electric ball valves are primarily used to shut off or connect the medium in the pipeline and can also be used for regulating and controlling fluid flow. They serve as pipeline pressure components in industrial automation process control.

automated ball valve Specification

Nominal Diamete NPS1/2"-48"DN15-DN1200
Connection type Flange/Welding/Socket Welding
Nominal Pressure 1.0-16MPa 150LB-900LB
Working temperature from -40 °C to 260 °C
Working Medium Water, Oil, Gas ect.
Body Material Stainless Steel (ASTM A351-CF8M,CF8)
Flange end standard JIS B2220, ANSI B16.5
Testing API 598, API 6D
Design Standard ANSI B16.34,API 603

 

electric motorized valve

electric actuated ball valvemotorized ball valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Causes and Diagnostic Methods for Electric Ball Valve Seizure

Step 1: First, open the transmission gearbox to check if severe rusting, bearing damage, or foreign object obstruction in the gearbox is causing the valve to malfunction. If these are not the causes, proceed to the next step.

Step 2: Perform a drain operation on the electric ball valve. If there is pressure in the valve chamber, it can be preliminarily determined that the seizure is due to the sealing seat being stuck. The sealing seat should normally have a lateral movement space of 0.003 inches. If the injected sealing grease hardens, debris gets stuck in the sealing seat gaps, or the sealing seat spring malfunctions, it can cause the sealing seat to get stuck and the ball valve to seize.

Step 3: If there is no pressure in the valve chamber during the drain operation, it can be determined that the seizure is caused by a large pressure difference between the valve chamber and the main pipeline. When the pressure difference is too great, the sealing seat presses tightly against the ball surface, increasing the operating torque and causing the ball valve to seize and malfunction.

Hot Tags: electric ball valve, China electric ball valve manufacturers, suppliers, factory, ball valve prevention, ball valve shipping, ball valve rigid couplings, ball valve non return valves, vee ball control valve, ball valve acoustic couplings