Flanged Floating Ball Valve Description
The ball of the flange floating ball valve is floating. Under the pressure of the medium, the ball can produce a certain displacement and press tightly on the sealing surface of the outlet to ensure the sealing of the outlet. The floating ball valve has a simple structure and good sealing performance, but the load of the working medium borne by the ball is all transmitted to the outlet sealing ring, so it is necessary to consider whether the sealing ring material can withstand the working load of the ball medium. This structure is widely used in medium and low pressure ball valves.
API 6D Flanged Ball Valve Specification
| Design and Manufacture | API 6D |
| Wall Thickness | API 6D |
| Face-to-Face Dimension | API 6D |
| Flange End Dimension | ANSI/ASME B16.5 (1" to 24") ANSI/ASME B16.47 (26" & up) |
| Butt-Weld End Dimension | ANSI/ASME B16.25 |
| Inspection & Testing | API 6D/API 598 |
| Fire Safe Design | API 607/BS 6755 |
| Material | Nace MR 0175 |
floating ball valve


Procedure for handling internal leakage of flange floating ball valve
- First check the limit of the valve to see if the internal leakage of the valve can be solved by adjusting the limit;
- First inject a certain amount of grease to see if it can stop the leakage. At this time, the injection speed must be slow, and at the same time, observe the changes in the pointer of the pressure gauge at the outlet of the grease injection gun to determine the internal leakage of the valve;
- If the leakage cannot be stopped, it may be that the sealing grease injected earlier has hardened or the sealing surface is damaged, causing internal leakage. It is recommended to inject valve cleaning fluid at this time to clean the sealing surface and valve seat of the valve. Generally, soak for at least half an hour. If necessary, soak for several hours or even several days. After the solidified material is completely dissolved, proceed to the next step. In this process, it is best to open and close the movable valve several times;
- Re-inject grease, open and close the valve intermittently, and discharge impurities from the back cavity of the valve seat and the sealing surface;
- Check in the fully closed position. If there is still leakage, inject reinforced sealing grease and open the valve cavity for venting at the same time. This can generate a large pressure difference and help seal. Generally, internal leakage can be eliminated by injecting reinforced sealing grease;
- If internal leakage still occurs, the valve must be repaired or replaced.